Osram Y-CONNECTOR User Manual Page 1

Browse online or download User Manual for Lighting Osram Y-CONNECTOR. OSRAM Y-CONNECTOR User Manual [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
OSRAM GmbH
Kunden Service Center
Customer-Service-Center (CSC)
Steinerne Furt 62
86167 Augsburg
Germany
Tel : +49 (0) 1803 677 - 200
(kostenpichtig / charges apply)
Fax.: +49 (0) 1803 677 - 202
www.osram.com
www.osram.de
40503008031352
4050300803135
Page 1 of 2
Y-connector
Fitting instructions
II 2009
Y-CONNECTOR_ma0902en_we1.01.indd
Y-CONNECTOR
B
A
A
A
Description
Function and application
The Y-connector is used to connect multiple sensor and control
units in a MULTI3/MULTIeco system or for connecting the
components of an EASY Color Control system.
The Y-connector is attached using the integrated adhesive pad.
Function
Two sockets are used to connect the system components with
the supplied connection cables. The third, vacant socket of the
Y-connector can be used to connect additional control units or
sensors.
Design
The Y-connector is made up of the following components:
RJ-11 sockets for device connections (A)
Adhesive pad (B)
Installation
Safety instructions
The Y-connector must only be installed and put into operation
by a qualied electrician.
The applicable safety regulations and accident prevention
regulations must be observed.
WARNING!
Exposed, live cables.
Danger of electric shock!
Only work on the Y-connector when the unit is
de-energised.
CAUTION!
Destruction of the Y-connector and other devices
due to incorrect installation!
Do not install the Y-connector in the same
housing with other parts that conduct mains
voltage.
Only connect the Y-connector to suitable
components.
For SELV, provide for adequate insulation
against parts that conduct mains voltage.
Do not wire the Y-connector with an external
voltage, especially not a mains voltage of 230 V.
Connecting devices
For the type and number of devices that can be connected via
the Y-connector, see the separate instructions for each device.
All sockets of the Y-connector are interconnected via 4 pins and
are equivalent.
Note:
An example of a wiring diagram is provided in the operating
instructions of the control units.
Page view 0
1 2

Summary of Contents

Page 1 - 40503008031352

OSRAM GmbH Kunden Service Center Customer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg GermanyTel : +49 (0) 1803 677 - 200 (kostenpichtig

Page 2 - Appendix

Page 2 of 235 mm16 mm18 mmAppendixTechnical dataCombined control and supply connection3x 4-pin modular 4p4c socketsBasic insulation as per IEC 664Conn

Comments to this Manuals